The crane is used as a stop valve on pipelines for drinking and household purposes, hot water supply, heating, compressed air, liquid hydrocarbons, as well as process pipelines transporting liquids that are non-corrosive to the crane materials. The use of ball valves as control valves is not allowed.

Dimensions, G 1/2 ” 3/4 „ 1 ” 1-1 / 4 „ 1-1 / 2 „ 2 ”
A, mm 49.5 56 67 76.5 89 107
B, mm 41.5 45.5 52 67 81 92
C, mm 97 97 120 128 145 145
Leak tightness class „A“
Working pressure (PN), bar up to 20
Maximal pressure (PN), bar 40
Type by effective diameter full bore
Ambient temperature, ℃ – 20 ÷ +60
Operating medium temperature, ℃ -20 ÷ 150
Ambient humidity, % 0 ÷ 80
Angle of rotation of the handle between the outermost positions, degrees 90º
Body Material Brass CW617N nickel plated