Angle valve for manual or automatic control of the flow of coolant through the heater. In the second case, it is completed with a thermostatic head or servo drive controlled by a room thermostat or controller. The use of control valves with a thermostatic head allows you to automatically maintain the desired temperature in the room with an accuracy of 1 ° C. The presence of polusgon makes it possible to mount and dismantle the valve without dismantling the pipeline. Maintainable. Pipe / pipe threads are internal / external, for thermostatic head or servo actuator – external.
| Size | Article | D | d | L | H | B | R | pcs/boxes | Thread for thermal head connection, mm |
| 20×1/2 | K0149.PRO | 29,2 | 19,2 | 16 | 76,6 | 62,2 | 1/2’’ | 92 | М30 х 1,5 |
| 25×3/4 | K0150.PRO | 35,7 | 24,1 | 18 | 79,2 | 61,6 | 3/4’’ | 80 | |
| Material of the terminations of combined fittings: Brass CW617N nickel-plated | |||||||||